| HWg-PWR: Supported M-Bus meters |
| |
| This list contains M-Bus (EN 13757-2, EN 13757-3) meters tested with HWg-PWR. HWg-PWR is an Ethernet M-Bus gateway that makes values from external M-Bus meters accessible over LAN (WEB - charts, SNMP, E-mail, MS Excel). |
| |
|
| |
| Energiezähler |
| |
|
ED 310.DB HWG
ED 310.DB HWG is a three-phase, static, two-rate electrometer for direct measurements up to 63A, with M-Bus and S0 interfaces – 3x230V/400V, (5)63A
* Manufacturer: ZPA
* Power: 3x230V/400V, (5)63A
* Measurement: Direct, max 63A
* M-Bus interface: Yes
* S0 interface: Yes |
|
| |
|
 |
ED 310.I.DB
ED 310.DB HWG is a three-phase, static, two-rate electrometer for indirect measurements, with M-Bus and S0 interfaces – 3x230V/400V, x/5A
* Manufacturer: ZPA
* Power: 3x230V/400V, x/5A
* Measurement: Indirect
* M-Bus interface: Yes
* S0 interface: Yes |
|
| |
|
DHZ 5/63-M-BUS
Single-phase electronic electricity meter for direct measurement up to 63A
* Manufacturer: NZR
* Power: 1x230V / 63A
* Measurement: Direct
* M-Bus interface: Yes |
|
| |
|
DHZ 5/65 M-BUS
Three-phase electronic electricity meter for direct measurement up to 65A
* Manufacturer: NZR
* Power: 3x230V/400V, 65A
* Measurement: Direct
* M-Bus interface: Yes |
|
| |
|
DHZ x/5A M-bus
Three-phase electronic electricity meter for indirect measurement
* Manufacturer: NZR
* Power: 3x230V/400V, 5(65)A
* Measurement: Indirect
* M-Bus interface: Yes |
|
| |
|
DBM23000
Three-phase electronic electricity meter for indirect measurement
* Manufacturer: ABB
* Power: 3x230V/400V, 5(80) A
* Measurement: Indirect
* M-Bus interface: Yes |
|
| |
|
ABB DELTAmax (DHM13007)
DELTAmax is a family of single-phase and three-phase electronic electricity meters for direct and indirect measurement.
Thanks to the way their M-bus datagrams are designed, any M-bus product by ABB can be easily supported.
* Manufacturer: ABB
* Family: DELTAmax (tested: DHM13007)
* Measurement: Direct or indirect
* M-Bus interface: Only three-phase electricity meters by ABB for direct or indirect measurement are equipped with the M-bus interface. For single-phase measurements, a single-phase electrometer (Odin single etc.) and an external M-bus adapter are used. |
|
| |
|
MGEIZ363, MGEIZ315
Single-phase and three-phase electricity meters by EIZ - SCHRACK. Tested with the MGEIZ163-C model.
* Manufacturer: EIZ - SCHRACK
* Power: 1x230V, 63 A / 3x230V/400V, 63 A
* Measurement: Direct
* M-Bus interface: Yes |
|
|
| |
| Wärmezähler |
| |
|
Sensonic II
Sensonic® is an electronic heat meter. The compact sensonic® II device and the sensonic® II flow sensor support flows of 0.6/1.5/2.5 m3/h.
* Manufacturer: ISTA
* Measures: Heat
* Flows: 0.6/1.5/2.5 m3/h
* M-Bus interface: Yes |
|
| |
|
|
sensonic® II calculator
Converter to connect ISTA heat meters to M-BUS
* Manufacturer: ISTA
* Measures: Heat
* M-Bus interface: Yes
* Limitation: Battery-operated device, allows only 64 reads over M-Bus per day. |
|
|
| |
| Andere |
| |
|
M-count 2C
Two-channel S0 pulse output converter to M-bus. The number of counted pulses is protected against power outage. Functionality is backed up with an internal, replaceable battery.
* Manufacturer: Günther Schell GmbH
* Input: 2x pulse input for S0
* Output: M-Bus interface
* Power: 230V + internal CR2032 battery
|
|
| |
|
|
OA-4108
Optical to M-bus converter for ABB electricity meters.
* Manufacturer: ABB
* Input: Optical port of the ODIN electricity meter
* Output: M-Bus interface
* Power: From the M-Bus |
|
|
| |
| Diagramme HWg-PWR |
| |
|
| |
|
| |
|
|