ePowerSwitch-8G Guard is a power control unit that enables remote power control of 8 devices over Intranet, Internet or locally through an RS-232 serial connection.
It also allows you to monitor 8 IP devices (server, router, camera...) and automatically reboot it in case of lock-up. Benefits:

+ Remote power control of 8 power outlets
+ Remote control an d administration over IP and RS-232
+ Dual Power input allows incrasing total load and security
+ Monitoring of 8 IP devices and automatic reboot function in case of lock-up
+ Power-up sequencing avoids in-rushes currents at start-up
+ Access protected by names and passwords (1 administrator and 8 user account)
+ Power-Up sequencing avoids in-rushes currents at start-up
+ Free definable labels for the device an the power outlet
+ Easy and fast configuration
+ Occupies only 1U of rack space
+ Status LEDs for power Input, network and power outlets
+ Firmware updateable over the LAN.

Features:

ON, Off and Restart Functions
The power outlet can be turned On/Off or restarted over IP or through an RS-232 serial connection.

Two seperate AC Power Inputs
To imporve the security an increase the local current load, the ePowerSwitch-8G has two seperate power inputs. The first one provided power for plugs 1 to 4 and the second one for plugs 5 to 8. This features is ideal for power management of servers with redundant power supplies.

IP Device Monitoring
Monitoring of up to 8 IP devices with automatic reboot function. The supervision can be performed using a Ping and/or a Scan command of 8 specific IP addressess and Port Numbers.

IP Security
Two Password levels : the administrator password allows configuration and access to the power outlet and 8 user passwords allows only access to the power outlet. 8 security masks allow you to grant or deny access to only a specific IP address or a group of IP addresses.

Restart Delay
The restart delay of power outlet can be set between 5 and 60 seconds

Sequentail power up/down
Avoids the risk for a power inrush to blow a fuse or circuit breaker in the data centre.

Labels
To avoid confusions, the administrator con define a label to the device and its power outlet

Easy configuration
The configuration con be done through a standard web browser, a serial console interface or a convenient Windows toll wich provides an easy and quick way to configure your ePowerSwitch especeally by the first settings of the Network parameters
 